It is possible to command even if it is manual and it is possible to set in 5-55% of ranges of the highest value for expiratory flow. It names the function to do an end-of-suction end recognition condition (the cycle off standard) in PSV in the self-regulation FlexCycle. When the air quantity of ventilation can not be achieved even if it reaches a pressure limit, the alarm of Vol Target Not Met is done in the caution. In other words, it is ventilated at the value which was computed from the pulmonary compliance for the taking air quantity of ventilation to become a set value.Ī variation every ventilation is limited to +/-6cmH2O. In the SPONT mode, it is ventilated in VTPS.Īt the time of this mode selection, the first time ventilation becomes either of 40% of the pressure limit or PEEP/CPAP pressure + 5cmH2O higher pressure.Ī ventilating-pressure is self-adjusted in the range of the pressure limit from either of 40% of the pressure limit or PEEP/CPAP pressure + 5cmH2O higher one. In the SIMV mode, an active-ventilation is given in VTPC and a spontaneous-respiration is given in VTPS. In the abbreviation of Volume Target Pressure Control/Volume Target Pressure Support, it is the meaning which is the same as the mode to be written with PRVC/VS in Servo300, Servo i. In April, 1998, -100 M of E and becoming ATC (the function to do a trigger level in the self-regulation), Time-Limited Demand Flow (the demand style additional structure to the spontaneous-respiration), Apnea A/CMV (the anaerosis back-up feature), AS (the pressure alarm level self-regulatory mechanism) were added. In June, 1997, it became -100 s of E, a mechanicaeration cable type manometer was changed into the digital bargraph display by the LED and a pressure trigger mechanism, too, was changed into the electronic type.Īn exhalation-valve control system, too, was improved and a response was improved. In E-100i, it abolished pressure cycle mode (Pressure cycle) with low frequency of library use, and it added "MO-DOSEREKUTA-" and an operation system was simplified. (Newport Medical Instruments) but were integrated into the revised version of E-100i (the mind of international) in March, 1991 with production rationalization of the NMI Inc. 100 A of E were the Japanese specification which was produced in entrusted in America NMI Inc. In January, 1987, it was improved in -100 A of E and an exhalation-valve unit was stored in the main unit underside.
In October, 1981, in the sale, in begun E-100, an exhalation-valve body was done with the external.
However, with the power of the continuous flow mechanism and the pressure relieving mechanism, it is more applicable to the adult than to the newborn baby. "It achieved necessary basic performance in the simple in the combination of the latest general technology" It is smallness, light weight, the multifunction and low-priced simple machine.